For your safety
Version: 4.3
───
15
AM8000 and AM8500
2.2.2
During operation
Avoid contact with DC link DC+ and DC-
Measure the voltage on the DC link test contacts DC+ und DC-. Ob-
serve the following delay times after disconnecting from the mains
supply:
• AX5101 to AX5125 and AX520x
5 minutes
• AX5140, AX5160 and AX5172
15 minutes
• AX5190 and AX5191
30 minutes
• AX81x8, AX8206 and AX8810
30 minutes
• AX8620 to AX8640
30 minutes
• AX5192 and AX5193
45 minutes
Do not work on live electrical parts
Do not open the motor while it is live. Ensure that the protective con-
ductor is connected properly. Never loosen electrical connections
when live. Only work on the motor when the voltage has dropped to
< 50 V. Disconnect all components from the mains and secure them
against being switched on again.
Do not touch hot surfaces
Check the cooling of the surfaces with a thermometer. Do not touch
the components during and after operation. Allow the components to
cool down for at least 15 minutes after switching off.
Avoid overheating
Operate the motor according to the technical specifications. Please
refer to chapter: "Technical data". Activate and monitor the tempera-
ture contact of the motor. Provide for sufficient cooling. Switch the
components off immediately if the temperature is too high.
Do not touch any moving or rotating components
Do not touch any moving or rotating parts during operation. Fasten
all parts or components on the machine or plant.
2.2.3
After operation
De-energize and switch off components before working on
them
Check the functionality of all safety-relevant devices. Carry out a
voltage test. Secure the working environment and the control cabi-
net against being switched on again. See chapter: Decommissioning