Number
Cause
Solution
13
Short-circuit in the voltage supply cable for the
holding brake [+]
Replace defective cable, then measure and
check
14
Inadequate power supply of the holding brake [+]
Check the settings in the configuration and
read out the electronic type plate of the motor
again
15
Short circuit or earth leakage in the motor
Replace defective motor, then measure and
check
16
Insufficient power supply
Check the settings in the configuration and
read out the electronic type plate of the motor
again
17
Interruption or crushing in the feedback cable
Check cables for broken wire or crushing. Re-
place defective cables, then measure and
check.
18
Feedback connector not fitted correctly
Check the position of the feedback connector
Loose fit of the feedback connector or no contact of
the plug contacts with the power socket of the mo-
tor.
Check the connector assembly. Contact Beck-
hoff Service if necessary.
19
Cooling water pipes and/or water connections
leaky or defective
Determine leakage
If necessary: Seal