The historical: There are 3 different sockets in the PSA models. The oldest socket is the 2-
pole, then came the 30-pole and finally came the 16-pole version.
2-pole
30-pole
16-pole
For the 30-pole version there is an adaptor which can be acquired on the Internet for approx.
30 euros.
For the 2-pole socket an adaptor must be produced. I dispatch all Pin assignment on inquiries.
Furthermore there are 3 different board computer versions. In detail the ReLight was checked
only in the newer version (from approx. 1998 upwards).
The ReLight has, from the software version 1.7 on, more than two different modes. Mode0 is
used for models before 1998 and Mode1 for newer models. The Default mode is 1. In mode 0
the voltage and the current are differently given. With older models the voltage and the
current are approx. 24% too high, because the calculation basis has changed with the newer
models. To switch the mode do the following:
1.) Put the ReLight to the vehicle and hold the “OK” key down
2.) Hold the "OK" key as long down until "MODE" appears then release the “OK” key.
3.) By pressing the "OK" key again you can switch the mode between 0 and 1.
4.) If you have put the desired mode, press the "Down" key and the device starts as usual.
Question:
How can I tell if I have an older version on-board computer?
At the start of the self-diagnosis the version of the ReLight is displayed. All versions smaller
than 32 have the older board computer – Version 32 and greater are the newer ones. Older
board computers provide no battery information.
From
software version 2.0
, in the same menu as in the mode menu, a voltage threshold can be
set. You can choose between OFF and a voltage between 102 and 111 volts. With the "Up and
Down” keys it is possible to switch between the mode and the warning threshold.