5.) Now the accumulators are charged to 100%, then a 5-hour overcharge phase starts. (If the
capacity was at 0% to the beginning of the charging phase the complete charge lasts 8 hours +
5 hours = 13 hours). The ReLight2010 can be let connected to the car if wished. Remark:
However, I recommend disconnecting the Relight from the car. This relieves the board
computer and extends the life span of the ReLight.
6.)
If the maintenance charge is concluded, the warning light „water refill needed” is on
again.
(*If the light “Water refill needed” was off before the
maintenance
it should be on
now). Now the battery charger does a 72 hours preservation load, besides, the electrolyte
level is held on maximum. Now the accumulator water can be refilled. Either you fill it in
during the running preservation load, or you separate the vehicle from the electricity supply
and fill in the water within 30 minutes after the separation. If you do not carry out the fill-up
of the water during the 30 minutes after separation of the charging plug, the maintenance
charge must be carried out once more.
7.)
Take the water container of the locking of the bonnet and fill it with some litres of
distilled water. Fill only little water and shake until the tube is completely filled with
water. Put the water container back to the locking of the bonnet and fill the container to
70-80%
8.)
I personally fill the water
after removing
the loading plug. Remove the loading plug (if
not already done) also remove the ReLight.
9.)
Remove the cover of the filling connections in the vehicle (if available) and clean the
connection carbines of dust and mud.
10.) Connect the connection tube with the first carbine. Begin with the right carbine. (The
locking ring of the water connection must be pulled – while retiring as well as while drawing
off the plug - to the back).
11.)
Hold the water container always full as long as the water runs slowly into the
accumulators.
After some litres drainage water will flow out off the corresponding drainage
tube. Separate the connection tube of the waterkit directly after water runs out the drainage).
The resigning water is distilled water, however, it should be caught and be decontaminated in
the canal. Repeat this procedure with the next connection on the left from topical (and so on).