![Beck 14-100 Instruction Manual Download Page 55](http://html1.mh-extra.com/html/beck/14-100/14-100_instruction-manual_2718148055.webp)
55
80-1403-01, Rev. 3
26-1
Ambient Extreme: High highest highest temperature recorded in the DCM-3 compartment
26-2
Ambient Extreme: Low
lowest temperature recorded in the DCM-3 compartment
27-1
Ambient Rating: Temp Lwr Lim temperature allowed before alarm asserted
27-2
Ambient Rating: Temp Upr Lim temperature allowed before alarm asserted
28
Position(deg/in/mm)
Position % (Relative Index 13) expressed in engineering
units of degrees
29
Unit Select(deg/in/mm)
unit of measure for Position (Relative Index 28), always in
for Group 14
30-1
Position Sense: Unit
unit of measure for DCM-3 sensing circuit that receives the
signal from the CPS-2, always volts
30-2
Position Sense: Pres V
displays the output shaft position voltage signal at the DCM-
2 from the CPS-2
31-1
CPS Ranges: CPS Output Unit unit of measure for CPS-2 output signal to the DCM-3,
always volts
31-2
CPS Ranges: CPS Zero%
this is the voltage from the CPS-2 to the DCM-3 that the
DCM-3 will interpret as 0% output shaft position
31-3
CPS Ranges: CPS Span
the voltage span from the CPS-2 for the maximum travel
of the output shaft. This is simply the upper range voltage
minus the lower range voltage
31-4
CPS Ranges: CPS RngLwr
the CPS-2 voltage signal corresponding to the extend end
of travel when Travel is set to the maximum range
31-5
CPS Ranges: CPS RngUpr
the CPS-2 voltage signal corresponding to the retract end
of travel when Travel is set to the maximum range
32-1
Position Limits: PosLwrLim
Position Lower Limit, the signal in percent allowed before
an alarm is asserted
32-2
Position Limits: PosUprLim
Position Upper Limit, the signal in percent allowed before
an alarm is asserted
33
Snsr Dir
the direction of output shaft travel that causes the CPS-2
signal to increase. Except in some custom configurations,
this direction should always be retract
34
MaxTravel(deg/in/mm)
the maximum output shaft travel for this model of
actuator
35
Travel(deg/in/mm)
amount of output shaft travel for 100% signal change