Setup Checklist Menu
(Block 3)
This is a summary of the parameters a
technician will want to make certain are correct for
installing an actuator. Most of these parameters
also appear elsewhere in the menu tree, and are
gathered here for convenience.
1
Actuator S/N
: The serial number as shown
on the actuator nameplate. (Serial Number,
page 5)
2
Actuator Dir
: The direction the output shaft
moves in response to an increasing Demand
signal. (DIRECTION OF OUTPUT SHAFT
TRAVEL, page 30)
3
Feedback
: Determines whether the analog
output signal representing the output shaft
position is enabled. (SHAFT POSITION
OUTPUT SIGNAL, page 31)
4
CPS Zero%
: This is the voltage from the
CPS-5 to the DCM-3 that the DCM-3 will
interpret as 0% output shaft position (OUTPUT
SHAFT 0% POSITION, page 30)
5
PositionUnit
: For Group 14 this is inches.
6
MaxTravel
: The maximum output shaft travel
for this model of actuator. (OUTPUT SHAFT
POSITION SENSING, page 28)
7 Travel
: Amount of output shaft movement for
100% signal change. (TRAVEL, page 29)
8 DemRngLwr
: Signal strength representing
0% Demand. (DEMAND, page 25)
9 DemRngUpr
: Signal strength representing
100% Demand. (DEMAND, page 25)
10 Dem Curve
: Whether Demand is interpreted
as linear or a curve. (DEMAND SIGNAL
CHARACTERIZATION, page 26)
11 DemLimLwr
: Below this level, the Demand
signal is considered invalid. (LOSS OF
DEMAND SIGNAL (L.O.S.), page 25)
12 LOS Mode
: Action on loss of demand signal.
(LOSS OF DEMAND SIGNAL (L.O.S.),
page 25)
13 LOS Pos
: Substitute Demand signal under
some LOS modes. (LOSS OF DEMAND
SIGNAL (L.O.S.), page 25)
14 FB RngLwr
: Signal strength used to
represent 0% shaft position. (CONFIGURING
FEEDBACK, page 31)
15 FB RngUpr
: Signal strength used to represent
100% shaft position. (CONFIGURING
FEEDBACK, page 31)
16 FB Curve
: Whether the Feedback
signal is transmitted as linear or a curve.
(CONFIGURING FEEDBACK, page 31)
17 Trq/Thrust
: Inactive for Group 14.
18 Thr Null
: Inactive for Group 14.
19 Thr Const
: Inactive for Group 14.
20 AlarmLevel
: Inactive for Group 14.
21 Ovt Prot
: Inactive for Group 14.
22 ShutDwnThr
: Inactive for Group 14.
23 StallProt
: Whether actuator motor will be
turned off if the Stall Time counter expires.
(STALL PROTECTION, page 23)
24 Stall Time
: The amount of time the motor will
run before Stall Protection is initiated. (STALL
PROTECTION, page 23)
25 Temperature Unit
: Unit of measure for
temperature sensing. (TEMPERATURE
SENSING, page 22)
26 StepSize
: The typical smallest Demand
change that will cause an output shaft
movement. (STEP SIZE, page 22)
27 LimitSwitch
: Modifies the behavior of Stop/
Limit alarm. (STOP/LIMIT INDICATION,
page 22)
28 AlarmPol
: Whether the solid state relay
opens on alarm or closes on alarm. (ALARM
OUTPUT CONFIGURATION, page 23)
29 Alarm Mask
: Which alarms cause the solid
state relay to change state. (ALARM OUTPUT
CONFIGURATION, page 23)
DCM-3 HART
Menus