MPS 500 – User Manual Rev. 2.1
BeamTec GmbH
Wolfgang-Paul-Str. 4, 89081 Ulm, Germany
http:
, e-mail: [email protected] tel.: +49 731 146620-0
12
Regulation mode
Power, Voltage or Current mode
Ripple Noise
Switching: 2% p-p (50 kHz)
Ramp Up time
0.1 …. 65 s
Communication Interface
RS232 and LAN/Ethernet 100Mb, Bluetooth in
standard
Type of control
Local or remotely
Arc Detection
Response time < 95 ns
Dimensions
418 mm x 270mm x 87 mm ( 2U high unit - 19”
standard )
Weight
6.1 kg
2.4
F
EATURES
:
Operating mode: DC
Two high-voltage outputs - the ability to support two independent magnetrons
without having to use an external switch
Fast response arc detection/suppression
Switched control methods (I, V, P) for maximum performance,
The ability to connect one active vacuum measuring head (optional)
Transparent interface with OLED display and desk light identification parameters
Built-in timer
Stable power operation from just 2W
High acceptance output impedance - ability to work with magnetrons of different
sizes
Suitable for working with one or two magnetrons
User-friendly interface with OLED display, keypad and rotary encoder