![BEA LZR-WIDESCAN Manual Download Page 8](http://html.mh-extra.com/html/bea/lzr-widescan/lzr-widescan_manual_2715851008.webp)
Page 8 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 8 of 16
75.5916.03 LZR-WIDESCAN 20180821
...
....
..
X X X X
...
....
..
1
2
3
A
4
5
6
B
7
8
9
C
F1
0
F2
D
.
.
Page 8 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 8 of 16
75.5916.03 LZR-WIDESCAN 20180821
HOW TO ADJUST THE SENSOR BY REMOTE CONTROL
Activate red spots on floor
Teach-in: install
Teach-in: pull-cord
Presettings
Restoring
Password
More
>Diagnostics
Value
Parameter
Value
Parameter
PRESS
2X
After unlocking, the
red LED flashes and the
sensor can be adjusted
by remote control.
To end an adjustment session,
always lock the sensor.
If the red LED flashes quickly after unlocking, enter an
access code from 1 to 4 digits. If you do not know the
access code,
cycle power
.
If necessary, select the corresponding detection field before selecting the parameter and changing the
value. The second LED indicates the detection field.
MOTION
PULL-CORD
PRESENCE
SAFETY
Return to previous menu or
display.
Select your
Language
before entering the
first LCD menu.
Within the first 30 seconds of power-on of the sensor
or later in the diagnostics menu.
Enter a
Password
if necessary.
Access advanced adjustments.
Displayed value = Saved value
Displayed value = Factory value
Scroll up or down.
Go to the
Diagnostics
menu.
Enter the LCD menu.
Select a folder, parameter, or value.
Confirm a value and exit edit mode.
Activate red spots on floor.
Launch POSITION WIZARD.
SHORT
PRESS
LONG
PRESS
HOW TO ADJUST THE SENSOR BY LCD
.