![BEA LZR-WIDESCAN Manual Download Page 15](http://html.mh-extra.com/html/bea/lzr-widescan/lzr-widescan_manual_2715851015.webp)
75.5916.03 LZR-WIDESCAN 20180821
Page 15 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 15 of 16
1
E1
2
E2
5
E5
6
E6
1
2
3
A
4
5
6
B
7
8
9
C
F1
0
F2
D
8
E8
75.5916.03 LZR-WIDESCAN 20180821
Page 15 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 15 of 16
E1: CPU-XXX
The sensor encounters an internal
problem
Replace sensor.
E2: XXX PWR
The internal power supply is faulty
Replace sensor
E2: IN SUPPLY
The power supply is too low or
too high
Verify power supply (Diagnostics > LCD).
E2: TEMP
The internal temperature is too
low or too high
Verify the sensor temperature (Diagnostics
>LCD).
Protect the sensor from direct exposure to
heat or cold.
INSTALL
The sensor requests a teach-in
Launch teach-in after angle adjustment.
All presence/safety outputs are activated.
E5: FLATNESS
Faulty teach-in
Make sure that the teach-in zone is clear
of objects and then launch install teach-in.
E5: TILT
Faulty teach-in due to tilt angle
Adjust tilt angle (max. 15° > Diagnostics
> LCD).
Launch install teach-in.
E5: AZIMUTH
Faulty teach-in due to lateral
angle
Adjust lateral angle (max. 45° >
Diagnostics > LCD).
Launch install teach-in.
E5: HEIGHT
Faulty teach-in due to mounting
height
Adjust mounting height
(max. 19’6”, min. 6’6”).
Launch install teach-in.
E5: TIME-OUT
Faulty teach-in
Relaunch install teach-in. Make sure that
there is no motion detection during at
least 5 seconds when LED starts flashing
red/green.
Slightly change your position and relaunch
an install teach-in.
E6: FQ OUT
Faulty sensor output 1
Replace sensor.
E8: ...
Faulty detection engine
If internal temperature is lower than
68 °F, wait until the heating process is
completed.
If temperature is higher than -4 °F, replace
the sensor.
ORANGLE LED is on
The sensor encounters a memory
problem
Replace sensor.
LED and LCD display
are off
Incorrect wiring
Check wiring.
Check for damaged pins or sensor
harness.
Door does not react
Service mode is activated
Exit service mode (see page 10).
Product does not
react to remote
control
Sensor is password-protected
Enter correct password. If you forgot
the code, cut and restore power supply
in order to access the sensor without
entering a password during 1 minute.
Motion detection
starts too late
Negative angle is too large
Reduce angle of the sensor.
TROUBLESHOOTING