Technology
LASER scanner, time-of-flight measurement (7 laser curtains)
Detection mode
Motion and presence
Max. detection field
Width: 1 x mounting height
Depth: 1.2 x mounting height
adjustable, depending on user settings
Thickness of first curtain
3
⁄
4
inch per 3 feet of mounting height
Typ. mounting height
6’6” – 19’6”
Min. reflectivity factor
> 2 % (of floor and object) (measured at max. 19’6” in safety field)
Typ. min. object size
6” @ 19’6” (in proportion to object distance)
Testbody
27
1
⁄
2
” × 11
3
⁄
4
”× 7
3
⁄
4
”
Emission characteristics
IR LASER: Wavelength 905 nm, max. output pulse power 25 W, Class 1
Visible LASER: Wavelength 650 nm, max. output CW power 3 mW, Class 3R
Supply voltage
12 – 24 VAC ±10% 12 – 30 VDC ±10% @ sensor terminal
Power consumption
< 2.5 W (heating: off) < 15 W (heating: eco or auto)
Response time
Typ. 100 ms (max. 500 ms)
Output
2 solid-state relays ( galvanic isolation, polarity free )
30 VDC (max. switching voltage) – 100 mA (max. switching current)
- in switching mode: NO/NC
- in frequency mode: pulsed signal (f= 100 Hz ±10%)
1 electro-mechanic relay (galvanic isolation, polarity free)
42 VAC (max. switching voltage) – 500 mA (max. switching current)
Input
30 VDC (max. switching voltage)
low < 1 V high > 10 V (voltage threshold)
LED signals
2 tri-colored LED: Output status / remote control response / error signals
Dimensions
7
3
⁄
4
” (H) x 6” (W) x 4” (D) (approx.)
Material / Color
PC/ASA / Black
Rotation angles on bracket
45° to the right, 15° to the left ( lockable )
Tilt angles on bracket
-10 – 5°
Protection degree
NEMA 4 / IP65
Temperature range
-22 – 140 °F
Vibrations
< 2 G
Norm conformity
EN 61000-6-2
EN 61000-6-3
EN 60950-1
EN 60825-1
EN ISO 13849-1 Pl “d”/ CAT2
EN 62061 SIL 2
EN 61496-1 ESPE Type 2
EN 12978
EN 50581
Specifications are subject to change without prior notice. All values measured in specific conditions.
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
TECHNICAL SPECIFICATIONS
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAinc.com