![BEA LZR-WIDESCAN Manual Download Page 7](http://html.mh-extra.com/html/bea/lzr-widescan/lzr-widescan_manual_2715851007.webp)
75.5916.03 LZR-WIDESCAN 20180821
Page 7 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 7 of 16
OK
2
75.5916.03 LZR-WIDESCAN 20180821
Page 7 of 16
75.5916.03 LZR-WIDESCAN 20180821
Page 7 of 16
LONG
Position the curtain closer to or farther away from the door by turning the screw at the top.
When the safety
function is required,
the red spots should be
as close to the door as
possible.
Negative angles reduce
the depth of the
detection fields.
Lock the sensor position by tightening the angle lock screw (see page 4).
Make sure the curtain is parallel to the door by adjusting one or both screws on the side.
PA
R
AL
LE
L A
NG
LE
TI
LT
A
NG
LE
Launch the POSITION WIZARD to position the detection field correctly in front of the door.
1. Push and hold OK to launch the POSITION WIZARD.
2. Rotate the sensor in order to align the center of the red spots with the center of the door. Push OK.
3. Rotate the sensor until the LCD screen validates the position. Push OK to exit.
CLOSER
AWAY
Remove the blue protection film from the laser window.
Activate the 2 visible laser spots by pressing
twice or pressing
on the remote
control.
LA
TER
AL
A
NG
LE
POSITIONING OF DETECTION FIELD