MANUAL SET-UP
(without remote)
MANUAL SET-UP
(without remote)
•
Set-up of the Wizard may be accomplished by the use of two Wizard mounted programming buttons.
The procedures below indicate how to program using these buttons.
•
The two set-buttons are located at the right side of the Wizard (as viewed when mounted to header).
To begin, briefly press the right button and move away from the sensing patterns.
TO RESET THE UNIT
to factory defaults including the access code.
•
Press and hold both buttons simultaneously until both red and green LED lights flash alternately
TO CUSTOMIZE SETTINGS FROM FACTORY DEFAULTS
•
To enter the customizing mode: Press the right button until the LED light flashes and then release
•
To return to standard mode: Press the right button again until the LED light stops flashing and then release
CUSTOMIZING MODE
•
The red LED light indicates the number for the parameter being altered ( 1 flash = parameter #1)
•
The green LED light indicates the value for the parameter being altered ( 1 flash means value = 1)
•
The right button enables selection of the parameter number being altered ( +1 for each press)
•
The left button enables alteration of the parameter ( +1 for each press)
PARAMETER NUMBER
(altered by the right button and
confirmed by
GREEN LED
)
PARAMETER
VALUES
(altered by the
left button and
confirmed by
RED LED
)
DEFAULT
VALUE
1
Radar Sensitivity
0-9
7
2
Relay hold time
0-9
0
3
Output configuration
1-6
4
4
Auto-learn
presence sensing
0-7
1
5
Detection mode
1-4
3
6
Immunity
1-3
2
7
IR sensitivity
1-2
2
8
Radar mounting
height
1-2
1
9
Not Used -
Must remain at 0
0
0
10
Door control function
1-3
3
11
SMR mode
0-2
0
12
IR curtain
1-2
2
Manual Push-Buttons
OBSOLETE