75.0127 V3 Jul. 2003 [Rev. 8/13/2004]
Page 2 of 17
SAFETY
PRECAUTIONS
MECHANICAL
INSTALLATION
COMPONENT ID
•
Shut off all power going to the header before attempting any wiring procedures.
•
Maintain a clean & safe environment when working in public areas.
•
Constantly be aware of pedestrian traffic around the door area.
•
Always stop pedestrian traffic through the doorway when performing tests that may result in
unexpected reactions by the door.
•
Always check placement of all wiring before powering up to insure that moving door parts will not
catch any wires and cause damage to equipment.
•
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of
installation.
1. Remove the cover from the unit as shown in picture “A”. After the Wizard is attached to the
header, the cover may be removed by inserting small screwdriver behind the Wizard and
gently prying cover off as shown in picture “B”.
2. Attach mounting template to the center of header as shown (C) – template should be 0”-2”
above bottom edge of header. Drill the hole marked for wire passage and drill pilot holes for
screw mounting (D).
NOTE: Flush mount with bottom of header is necessary for for all neagtive IR angles.
3. Insert mounting screws about halfway in (F shown on next page), and install the Wizard onto
the screws. When in place, tighten screws to secure to header. Leave cover off until
mechanical adjustments are complete.
CABLE
COVER
MOUNTING SCREWS
MOTION SENSOR
FRONT LENSES
I.R. REMOTE RECEIVER
PRESENCE SENSOR
A
B
LED INDICATOR
MANUAL SET-UP
BUTTONS
2
nd
ANTENNA STORAGE
D
0-2”
BOTTOM OF DOOR HEADER
C
WIZARD MOUNTING
TEMPLATE
OBSOLETE