14
15
4.5 DC protector
The DC protector turns to “OFF” (2) automatically when electric device
being connected to the generator is operating and current above the
rated flows. To use this equipment again, turn on DC protector by
pressing its button to “ON” (1)
(1) “ON”
Direct current is output.
(2) “OFF”
Direct current is not output.
CAUTION
• Reduce the load of the connected electric device below the specified
rated output of the generator if the DC protector turns off. If the DC
protector turns off again, stop using the device immediately and
consult our company authorized dealer.
4.6 Engine smart control (ESC)
①
(1) “ON”
When the ESC switch is turned to “ON”, the economy control unit
controls the engine speed according to the connected load. The results
are better fuel consumption and less noise.
(2) “OFF”
When the ESC switch is turned to“OFF”, the engine runs at the rated
r/min(4500r/min) regard-less of whether is a load connected or not.
TIP:
The ESC must be turned to“OFF”when using electric devices that
require a large starting current, such as a compressor of a submergible
pump.
4.7 Fuel tank cap
Remove the fuel tank cap by turning it counterclockwise.
4.8 Ground (Earth) terminal
Ground (Earth) terminal (1) connects the earth line for prevention of elec-
tric shock. All electrical tools and appliances operated from
this generator, must be properly grounded by use of a third wire or be
“Double Insulated”
CONTROL FUNCTION
CONTROL FUNCTION