Page 19
NOTE:
Approved fluids include Shell Tellus® S2 M 32 Hydraulic Fluid, Dexron® III / Mercon® automatic
transmission fluid, Pro-Select™ AW-32 Hydraulic Oil or 10WAW-ISO viscosity grade 32 hydraulic oil. It is not
recommended that fluids be mixed, to top off the reservoir tank during initial set-up use Shell Tellus® S2 M 32
Hydraulic Fluid only.
3. However, you
MUST
check the fluid level before each operating. If not filled, proceed with the following steps:
1) Remove the vented reservoir dipstick, which is located in front of the engine on top of the reservoir tank.
See
FIGURE 16.
WARNING!
Much of the original fluid has been drawn into the cylinder and hoses. Make certain to refill
the reservoir to prevent damage to the hydraulic pump.
DO NOT overfill.
2) Check the fluid level using the dipstick.
See FIGURE 16 below and FIGURE
25 in Page
30
.
3) Replace the vented dipstick securely, tightening it until the top of the threads are flush with top of the pipe.
4) Disconnect the spark plug and prime the pump by pulling the recoil starter as far as it will go. Repeat
Approximately 10 times.
5) Reconnect the spark plug wire and start the engine, following instructions in the Engine Operator’s manual.
6) Use the control handle to engage the wedge to the farthest extended position. Then retract the wedge.
7) Refill the tank as specified on the dipstick if necessary.
NOTE:
Failure to refill the tank will void the splitter’s warranty.
8) Extend and retract the wedge 12 complete cycles to remove any trapped air in the system (the system is
“self- bleeding”).
9) Refill the reservoir within the range marked on the dipstick if necessary. See FIGURE 25 in Page 30.
NOTE:
Some fluid may overflow from the vent plug as the system builds heat and the fluid expands and seeks a
balanced level.
(FIGURE
16)