Microseparator™ Coolant Systems Transport, Installation, & Initial Startup
M000005_A - V Twin Ultra Transport & Installation 5.2-EN TM
37/78
12
Microseparator™ Initial Start Up
Prior to beginning operation of the automatic Microseparator™ for the
first time, some preliminary checks and actions are necessary. PLEASE
FOLLOW THESE INSTRUCTIONS CAREFULLY.
Remove access cover from scraper drive assembly and check:
1.
Main drive belt for proper tension. Adjust if necessary.
2.
Scraper drive tension and adjust if necessary.
Turn rotor by hand and check freedom from noise and ease of rotation.
Remove any lashings or coverings that may be protecting parts during
shipment.
All assemblies in this area paying careful attention to the limit switches
and stopper assembly. Both switches should be CLOSED in the UP
position.
Check centrifuge mounting stand for proper lagging and support.
Open control console and check for the following:
1.
Main power breaker is open, as well as auxiliary circuit breakers.
2.
Close main power breaker in Microseparator™ control panel and
check voltage.
3.
Close breaker and check incoming voltage and at transformer
secondary.
4.
Close remaining circuit breakers.
5.
Disconnect air supply.
This prevents operation of pneumatic
devices during initial tests.
Begin operational checks with the Microseparator™ running. SERIOUS
MECHANICAL DAMAGE CAN OCCUR SHOULD THE ELECTRICAL
CONTROLS INITIATE A CLEANING CYCLE WHEN THE CENTRIFUGE IS
SPINNING. A LARGE HEX SOCKET MAY DEPRESS AGAINST A LARGE HEX
NUT THAT IS ROTATING IF THE CONTROLS ARE NOT SET CORRECTLY.
SINCE THE AIR HAS NOT BEEN CONNECTED, THE ABOVE OCCURRENCE
IS NOW IMPOSSIBLE.
1.
"JOG" Microseparator™ drive motor by pressing SEPARATOR and
then START from the operator interface screen. Immediately
press the EMERGENCY STOP button (Hold in for at least 15
seconds) and observe direction of rotation. (See directional arrow
on cover adjacent to motor).
2.
Release EMERGENCY STOP. Again press the SEPARATOR
BUTTON and then the START button. Let Microseparator™ come