56
56
Enter the desired block length.
NOTE:
It is recommended that the transmit Block Size for a particular
terminal port be no less than 10 characters due to resulting performance
degradation.
For example, if you enter "255", the Telplex will respond with:
+------+------+------+------------+
| Port | Block|Local | Status |
| | Size |Access| Messages |
+------+------+------+------------+
| 2 | 255 | NO | OFF |
+------+------+------+------------+
Set Block Size.......1
Set Local Access.....2
Set Status Messages..3
Enter Request or X to Exit:
If you now wish to change the current Local Access for Port 2, type "2" in
response to the prompt.
IMPORTANT:
A terminal port must have Local Access enabled in order
for the device connected to that port to access System/Local mode (see
Section 4.3.1
). If Local Access is disabled for all terminal ports, the only
way to access System/Local mode is by pressing the
SELECT
switch
on the front panel for less than three seconds. The Telplex's active
terminal port will be Port 1.
The Telplex will respond with:
Local Access Enable ? (Y/N):