To access Local or Remote Unit Configuration mode for either type of
Telplex, use the following procedure:
1.
Connect a dumb terminal or a computer emulating a dumb
terminal to the desired terminal port (factory default is Port 1).
Make sure your terminal device is configured to operate at the
same serial parameters as the terminal port on the Telplex.
Factory default is 9600 baud rate, 8 bit word size, 1 stop bit, no
parity, and XON/XOFF handshaking disabled.
2.
Send the Escape Code Sequence (one second delay followed by
+++
and another one second delay). If you are programming a
multi-drop unit, you will receive the System Menu similar to the
following for the TX104:
TELPLEX TX104 SYSTEM MENU
Local Unit Configuration......1
Remote Unit Configuration.....2
Mux Mode......................3
Local Diagnostics.............4
Remote Diagnostics............5
Access Local Modem............6
Enter Request
:
If you are programming a standard unit, you will receive the Local
Mode menu similar to the following for the TX104:
3.
If you are programming a multi-drop unit, Type "1" for Local Unit
Configuration or "2" for Remote Unit Configuration in response to
the prompt. If you are programming a standard unit, type
Control-
T
for Local Unit Configuration or
Control-R
for Remote Unit
Configuration. From this point on, configuration of the Telplex is
accomplished by following the menus that prompt you.
Summary of Contents for Telplex TX102
Page 24: ...18 20 DTR Input Data Terminal Ready Enable disable the receiving of characters ...
Page 41: ...35 Self test passed ...
Page 55: ...49 Press any Key to continue ...
Page 58: ...52 Set Stop Bits 4 Set RTS DSR Pass Through 8 Enter Request ...
Page 72: ...66 Figure 9 ...
Page 99: ...NOTES NOTES ...