TX104/TX108 EIA-422
TX104/TX108 EIA-422
DB-25 FEMALE
DB-25 FEMALE
NOTE:
The EIA-422 port will give you the capability of using a cable up
to 4000 feet between two Telplex units.
3.5.2.2
3.5.2.2
TX102 CABLE CONNECTION
TX102 CABLE CONNECTION
If you wish to connect the composite port of a local TX102 to a remote
Telplex via cable, use the
COMPOSITE EIA-232
port on the back panel
of the TX102. You must program the unit to use a Line Type of Direct
(see
Section 5.8
). See
Section 3.5.1.2
for the pin/signal definition of the
composite port.
IMPORTANT:
When connecting a TX102 to a remote Telplex via cable,
you must use the EIA-232 composite port on the remote unit. This port is
usually connected to an external modem. Do not use the EIA-422 port
on the remote unit.
Some remote Telplex models will require an RJ-45 adapter to convert
the EIA-232 composite port's DB-25 connector to an RJ-45 connector.
The following Telplex models require an adapter to connect to the TX102
via cable: TX104, TX108, and TX24-V41B module. The adapter
required for these models is 25FRJ45PC-1. The pinout for this adapter
and the required cable are shown in
Appendix A.4.4
.
RX+
TX+
TX-
SGND
CTS
16
7
5
3
2
1
PGND
14
RX-
DTR
20
20
14
1
2
3
5
7
16
DTR
RX-
PGND
CTS
SGND
TX-
TX+
RX+
Figure 6
Summary of Contents for Telplex TX102
Page 24: ...18 20 DTR Input Data Terminal Ready Enable disable the receiving of characters ...
Page 41: ...35 Self test passed ...
Page 55: ...49 Press any Key to continue ...
Page 58: ...52 Set Stop Bits 4 Set RTS DSR Pass Through 8 Enter Request ...
Page 72: ...66 Figure 9 ...
Page 99: ...NOTES NOTES ...