![background image](http://html1.mh-extra.com/html/bayrol/automatic-ph/automatic-ph_instructions-for-use-manual_2713053027.webp)
Hose replacement dosing pump:
The indicated amount of maintenance is just the minimum
requirement. The frequency of maintenance depends on
the intensity of use.
The frequency of maintenance is determined by the appli-
cable, country-specific requirements! This may result in
considerably shorter maintenance intervals; the relevant
country-specific specifications and standards must be
observed.
NOTE
Only use original BAYROL Technik components. The use
of third-party components can lead to malfunction
during operation. BAYROL Deutschland GmbH disclaims
all liability and warranty for this.
MAINTENANCE PLAN
Weekly check:
–
Make sure you keep your filter system in perfect condition.
–
Check the pH value, preferably with a BAYROL Technik
Electronic Pool Tester.
–
Carry out a visual inspection of the system for leaks in all
components, lines and hoses.
Annual maintenance:
–
Replace the pH sensor and calibrate it.
–
Replace the dosing pump hoses.
–
Check the pH-injection valve and replace it if necessary.
17