14
CARD SWIPE INSTALLATION
Please contact Baytek Games if any further questions. (920) 822-3951 Ext. 1102
The Trolls game is pre-wired with a UCL (Universal Card Link) connector to accept Card Swipe
systems from many different manufactures.
Please follow these instructions to make full use of this capability.
Notes:
- Many card swipe systems have a voltage threshold that can be adjusted in the card swipe menu.
Please set this “Game Drive Threshold” to 2 Volts.
Game Adjustments:
On the motherboard inside the blue station main door, set dipswitches #1 and #2 to ON. (1 Credit per play)
On the 4 door boards inside all 4 main doors, set dipswitches #1 to ON, all others OFF. (1 mercy ticket)
Option #1:
Card swipe systems may come with a standard
9 pin Molex connector. This is the UCL connector.
Simply plug this connector into your
card swipe reader.
Option #2:
If your card swipe systems does not have a standard 9 pin
Molex connector, then you will have to splice wires into the
AACE5169 harness.
Black wire is ground. (common)
White wire is coin signal.
Red wire is +12 Volts DC
This would
normally plug
into coin
mechanism.
UCL Connector
Card Swipe system cable
would be plugged into this
connector.
AACE5169
UCL Connector
Card Swipe system cable
would be plugged into this
connector.
AACE5169