Installing and Connecting the TokenSpeed Module
893-01019-A
3-9
•
Port 2:
— Act LED lights when software is loaded from flash memory.
— Ins LED lights when software loading is complete and the system begins
executing.
•
All LEDs turn off when the module has started up successfully.
•
Ins LEDs on all ports toggle on and off, until the first port inserts successfully.
On the TokenSpeed module, the following sequence occurs:
•
Port 1:
— Act (activity) LED lights during switch memory test.
— Ins (inserted) LED lights during management bus test.
•
Port 2:
— Act LED lights while the module waits for software download from the
MCP.
•
All LEDs turn off when the module has started up successfully.
•
Ins LEDs on all ports toggle on and off until the first port inserts successfully.
Configuring the TokenSpeed Module
The TokenSpeed module is shipped preconfigured with the configuration settings
listed in
Table 3-3
. If transparent switching and no spanning tree operation are
appropriate for your network, no further configuration is necessary.
Table 3-3.
Factory default configuration settings
Parameter
Factory default
Possible settings
Switching mode
Transparent
Transparent, Source Route,
Source Route Transparent
Spanning Tree Protocol
None
None, IEEE, IBM
State
Enabled
Enabled, Disabled
Port type
Station
Station, Hub, Bay/SNPX RO,
RI–other, RO–other
Ring speed
16 Mb/s
16, 4, Auto
Speed sense
Disabled
Disabled, Enabled
TKNSPD.BK Page 9 Thursday, July 17, 1997 11:43 AM
Summary of Contents for Centillion 5000 5000BH
Page 6: ...vi 893 01019 A TKNSPD BK Page vi Thursday July 17 1997 11 43 AM ...
Page 12: ...xii 893 01019 A TKNSPD BK Page xii Thursday July 17 1997 11 43 AM ...
Page 44: ...TKNSPD BK Page 16 Thursday July 17 1997 11 43 AM ...
Page 50: ...TKNSPD BK Page 6 Thursday July 17 1997 11 43 AM ...
Page 70: ...TKNSPD BK Page 4 Thursday July 17 1997 11 43 AM ...