9. Operating Instructions – Change Program
9-58
HomeChoice
APD Systems Patient At-Home Guide October 2, 2009 07-19-61-244
WARNING
Your Night Fill Volume in milliliters (mL) should normally not exceed
the values shown in Table 19-7 on page 19-15. Contact your dialysis
center to confirm your Night Fill Volume if it exceeds this volume.
Exceeding this volume can result in an increased intraperitoneal
volume (IIPV) situation.
IIPV could result in a feeling of abdominal discomfort, serious injury,
or death. See page 18-58 for IIPV symptoms or if IIPV is suspected.
Additional care should be taken to monitor for IIPV symptoms for
those patients not able to communicate essential information to their
caregiver during treatment.
Night Fill
Volume
Volume of solution used for each cycle based on your
prescription.
Minimum setting is 60 mL
Maximum setting is 1000 mL
Default setting is 250 mL
Setting increments:
–
1 in the 60 to 100 mL range
–
10 in the 100 to 500 mL range
–
50 in the 500 to 1000 mL range
Night Tidal
Volume %
Volume of fluid drained and refilled during each cycle. This is
expressed as a percentage of the initial Fill Volume.
Minimum setting is 5%
Maximum setting is 95%
Default setting is 5%
Setting increment is 5%
h
NOTE:
When the Therapy type is changed from CCPD to Tidal, the Night
Tidal Volume % reverts to the default setting of 5%.
Table 9-17. Hi-Dose Tidal Settings – Low Fill Mode
(Continued)
Setting
Description
NITE FILL VOL: ML
NITE TIDAL VOL: %
Summary of Contents for HomeChoice
Page 12: ...Section 1 Glossary 1 Glossary...
Page 27: ...Section 2 User Assistance Information 2 User Assistance Information...
Page 30: ...Section 3 Warnings and Cautions 3 Warnings and Cautions...
Page 47: ...Section 4 Indications for Use 4 Indications for Use...
Page 50: ...Section 5 Description 5 Description...
Page 67: ...Section 6 Environmental Conditions 6 Environmental Conditions...
Page 70: ...Section 7 Setup and Check out 7 Setup and Check out...
Page 75: ...Section 8 Operating Instructions PRO Card and Modem 8 PRO Card and Modem...
Page 94: ...Section 9 Operating Instructions Change Program 9 Change Program...
Page 157: ...Section 10 Operating Instructions Make Adjustments 10 Make Adjustments...
Page 174: ...Section 11 Operating Instructions Prepare for Therapy 11 Prepare for Therapy...
Page 201: ...Section 12 Operating Instructions Perform Therapy 12 Perform Therapy...
Page 224: ...Section 13 Operating Instructions End Therapy 13 End Therapy...
Page 237: ...Section 14 Operating Instructions Effluent Sampling 14 Effluent Sampling...
Page 244: ...Section 15 Cleaning 15 Cleaning...
Page 248: ...15 Cleaning 15 4 HomeChoice APD Systems Patient At Home Guide October 2 2009 07 19 61 244...
Page 249: ...Section 16 Maintenance 16 Maintenance...
Page 251: ...16 Maintenance 16 2 HomeChoice APD Systems Patient At Home Guide October 2 2009 07 19 61 244...
Page 252: ...Section 17 Storage 17 Storage...
Page 254: ...17 Storage 17 2 HomeChoice APD Systems Patient At Home Guide October 2 2009 07 19 61 244...
Page 255: ...Section 18 Troubleshooting 18 Troubleshooting...
Page 324: ...Section 19 Technical Data 19 Technical Data...
Page 345: ...Section 20 Quick Reference 20 Quick Reference...
Page 368: ...Index Index...