Operating description
Tab.68 Behaviour of the electrical back-up
Value of the parameter
DP051
Operating description
0
The system gives priority to the heat pump during domestic hot water production.
Recourse to the electrical back-up is only taken if the DP090 time delay has elapsed in domestic hot
water mode, unless hybrid mode is activated. In that case, hybrid logic takes over.
1
Domestic hot water production mode gives priority to comfort by accelerating domestic hot water pro
duction by simultaneously using the heat pump and the electrical back-up.
In this mode, there is no maximum time for domestic hot water production as the use of the back-ups
helps to ensure domestic hot water comfort more quickly.
7.6
Reading out measured values
The measured values are available in the Information menu of the
different PCBs.
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.69 Choosing the menu
Counters
Selection
Measured values on circuit A
Choose the EHC–06 menu
Measured values on circuit B
Choose the SCB-04 menu
Measured values connected to the
operation of the heat pump
Choose the EHC–06 menu
Tab.70 Values available (X) in the sub-menus EHC–06, SCB-04
Parameter
Description
Unit
EHC–06
SCB-04
AM002
"Silent mode" status
X
AM010
The current pump speed
%
X
AM012
Current main status of the appliance.
See
Control system sequence chapter
X
X
AM014
Current sub status of the appliance.
See
Control system sequence chapter
X
X
AM015
Is the pump running?
X
AM016
Flow temperature of appliance.
°C
X
AM019
Water pressure of the primary circuit.
bar
X
AM027
Instantaneous outside temperature
°C
X
X
AM056
Wate flow rate in the system
l/min
X
AM091
Seasonal mode active (summer / winter)
0: Winter
1: Frost protection
2: Summer neutral band
3: Summer
X
X
AM101
Internal system flow temperature setpoint
X
CM040
Measure Zone Flow Temperature or DHW
temperature
°C
X
CM060
Current Pump speed of zone
%
X
DM001
Domestic Hot Water tank temperature (bottom sensor) °C
X