Status signals
Description
Code
Error code
4
(4 times red signal) Fan fault
e[34
Error code
5
(5 times red signal) Parameter error
e[00
/
e[01
Error code
6
(6 times red signal) Miscellaneous
The fault codes can be read with the
Recom
service software, a suitable
controller or a service tool.
Press the
J
key for 5 seconds: The status signals will
flash red quickly and the boiler will start its reset
procedure. The boiler will also start an automatic venting
cycle lasting around 4 minutes. If the error code continues
to display, search for the cause in the error table and apply
the solution.
The fault codes from the status signals are related to the fault codes
that can be read by the
Recom
software or a suitable controller. The
meaning of the error codes is given in the error table:
Lock out (Status signals)
Status
signals
Description
Probable causes
Checking / solution
Error code 1
(1 times red
signal)
Sensor fault,
temperature fault or
flow fault
4
Sensor not or badly
connected
4
Bad connection
4
Non-existent or
insufficient circulation
4
Water circulation direction
reversed
4
Sensor fault
4
Check the wiring
4
Check that the sensors are operating correctly
4
Check that the sensor has been correctly fitted
4
Vent the air in the heating system
4
Check the water pressure
4
Check the cleanliness of the heat exchanger
4
Check the circulation (direction, pump, valves)
4
Replace the sensor if necessary
Error code 2
(2 times red
signal)
Maximum
temperature of heat
exchanger or control
unit exceeded
4
Non-existent or
insufficient circulation
4
Sensor not or badly
connected
4
Bad connection
4
Sensor fault
4
No air supply or
insufficient air supply
4
No flue gas flow or
insufficient flue gas flow
4
Circulation
4
Vent the air in the heating system
4
Check the water pressure
4
Check the cleanliness of the heat exchanger
4
Check the circulation (direction, pump, valves)
4
Check the wiring
4
Check that the sensors are operating correctly
4
Check that the sensor has been correctly fitted
4
Replace the sensor if necessary
4
Check air supply
4
Check flue gas flow
4
Replace seals
Error code 3
(3 times red
signal)
Ignition fault:
4
5 burner start-
up failures
4
False flame
signal
4
5x Flame loss
4
No ignition
4
Ignition arc, but no flame
formation
4
Presence of the flame but
insufficient ionization (<1
µA)
4
Check the wiring
4
Check breakdown to earth
4
Check the condition of the burner set
4
Check the earthing
4
Check that the gas valve is fully opened
4
Check the supply pressure
4
Purge the gas supply to remove air
4
Check the operation and setting of the gas valve unit
4
Check that the air inlet and flue gas discharge flues
are not blocked
4
Replace the ionization/ignition electrode