5.9
Electrical diagram
R000291-A
P
230V, 50Hz
L N
MAINS
1
3
2
BR
BL
GN/
YW
PC
RS232
1
2
1
2
1
2
2
3
1
PSU
TA
TR
FS
HL
6
7
8
9 10 11 12 13
1
2
3
5
SENSORS
E
IT
IT
HMI
MAINS
SENSORS
PUMP PWM
PUMP
3WV
RS232
PUMP
PUMP A
1 2 3
BK
BL
GN/
YW
3WV
3WV
1 2 3
BK
BL
BR
1 3 2
PUMP
1 2 3 4
BK
BK
PWM
PUMP
RS232
Connecting a computer
PUMP A
Circulation pump
TR
Return sensor
IT
Ignition transformer
3WV
3-way valve
TA
Flow sensor
E
Ignition/ionization electrode
HL
Safety thermostat
PSU
Storage parameter
P
Power supply
FS
Flow switch
HMI
Connection box
5.10 Filling the system
5.10.1.
Water treatment
WARNING
Do not add chemical products to the central heating water
without consulting
BAXI
. For example: antifreeze, water
softeners and/or products to increase or reduce the pH
value. These may cause faults in the boiler and damage
the heat exchanger.
Flush the central heating installation with at least 3x the
volume of the central heating installation. Flush the DHW
pipes with at least 20 times the volume of the pipes.
For an optimum functioning of the boiler, the water of the installation
must comply with following characteristics:
5. Installation
Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24