8.0 Annual Servicing
15
8.2
Preparation (Cont)
8. Remove the two screws inside the flue spigot
(Fig. 31).
9. Slide the fire combustion box forward to
disengage it from the flue spigot and lift away
(Fig. 32).
8.3
Removal of Controls
(Fig. 33)
1. Undo the screw to the lower left hand side of
the fire that secures the gas tap bracket to the
combustion box.
2. Undo the two screws retaining the controls to
the combustion box.
3. Withdraw the complete controls assembly
from the fire.
NOTE:
On refitting the controls assembly,
ensure that the tongue on the controls
mounting plate engages in the corresponding
slot in the combustion box lower panel.
Flue
Spigot
Boiler Hood
Controls Assembly
Fig. 31
Fig. 32
Fig. 33