8.0 Annual Servicing
17
8.6
Cleaning the Combustion Box &
Coals
1. Remove any deposits from the firebed base
panel (Fig. 37).
2. If necessary the coals can be cleaned with a
very soft brush, and can be retouched using the
black stain supplied with the fire.
3. Refit the burner to the controls mounting plate
and replace the controls assembly in the
combustion box (Fig. 38).
8.7
Replacing the Fire
1. Once the boiler has been serviced, the fire can
be replaced. Refer to the boiler installation and
servicing instructions.
2. Slide the fire combustion box into position
ensuring that the flue spigot fits into the boiler
downdraught divertor. Fit and tighten the two
screws inside the flue spigot (Fig. 39) and
replace the two screws into the boiler base tray
(Fig. 41).
3. Reconnect the gas supply and test for
soundness (Fig. 40).
4. Replace all the loose coals, side cheeks, rear
and front coals as described in “Arranging the
Coals”. Refit the fender assembly.
Retaining
Screw
Burner
Controls Assembly
Controls Mounting Plate
Flue
Spigot
Boiler Hood
Fire Gas Supply Pipe
Firebed Base Panel
Boiler Downdraught
Divertor
Fig. 37
Fig. 38
Fig. 39
Fig. 40
Fig. 41