9.0 Changing Components
20
9.4
Gas Tap
1. Undo the three retaining screws and remove
the controls assembly from the fire combustion
box (Fig. 51).
2. Undo the two screws holding the bezel to the
gas tap bracket. Remove the bezel and control
knob (Fig. 52).
3. Undo the thermocouple nut from the base of
the gas tap, and disconnect the three gas pipes
from the tap body (Fig. 53).
4. Disconnect the electrode lead from the igniter
unit (Fig. 53).
5. Undo the two screws holding the gas tap to its’
bracket. Remove the tap, slackening the gas
pipes at their other connections if necessary
(Fig. 53).
6. Fit the new tap in reverse order.
9.5
Igniter Unit
(Fig. 54)
1. Remove the gas tap as described above.
2. Prize the circlip off the tap control shaft. Draw
the igniter unit off the shaft and replace with the
new one.
3. Fit the new circlip.
9.6
Electro-Magnetic Unit
(Fig. 54)
1. Undo the three retaining screws and remove
the controls assembly from the fire combustion
box (Fig. 51).
2. Undo the thermocouple nut from the gas tap.
3. Undo the electro-magnetic unit retaining nut
and withdraw the unit.
4.Fit the new unit and replace the nut.
After changing components replace all the
coals, side cheeks, back piece and underbed
as described in “Arranging the Coals”.
CAUTION:
The coals are extremely fragile
and must be handled accordingly. Gloves
should be worn and any inhalation of the dust
should be avoided. Keep the coals away from
children at all times. Never use coals other
than those originally supplied or Genuine Baxi
Spare Parts. Never put additional coals on the
fire.
Electrode
Lead
Igniter Unit
Thermocouple
Nut
Bezel
Control
Knob
Gas Tap
Assembly
Thermocouple
Nut
Igniter Unit
Electrode
Lead
Circlip
Electro-Magnetic
Unit
Retaining
Nut
Fig. 52
Fig. 53
Fig. 54
Controls Assembly