products of combustion with consequent health hazards.
!
Recommend that the appliance should be serviced by a competent person at least
annually.
14. SERVICING PARTS AND REPLACEMENT
!
Always turn off the gas and isolate the electric supply before commencing any
servicing and make sure that the appliance is cold. (The inlet ‘T’ connector for this
appliance incorporates an isolating valve).
!
This product uses fuel effect pieces, burner compartment rear wall and gaskets
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to eyes,
skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum. To
ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that
the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and
may be disposed of at a tipping site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these articles, but we recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking.
!
Check that the appliance is clean and that soot or debris is not blocking the gaps
between the ceramic fuel effect pieces causing an imperfect flame.
!
Check that soot or debris is not impairing the electrode spark or pilot burner.
!
Check that soot or debris is not blocking any of the slots in the main burner.
!
Remove any lint from the components.
!
After servicing, make sure that the ceramic fuel effect pieces are replaced correctly
as described in the installer and owner guide supplied with the ceramic fuel effect.
The installer and owner guide supplied with the ceramic fuel effect should have
been placed inside or attached to this guide by the installer.
!
Always test for gas soundness and spillage after servicing the appliance and check
operation of all controls
.
(Do not use leak detection sprays on this appliance.
Sprays may affect the operation of electrical components. Keep all liquid detection
fluids clear of electrical components).
14.1 To replace the burner plaques. (See Figure 42)
!
Remove the ceramic fuel effect and ceramic back wall.. The plaques can be then be
removed as follows without removing the fascia or fire front casting / fire front.
!
Remove the plaques clamping strips by detaching 6 screws.
Page 36