If any other non-sealed gas appliances are installed in connecting rooms, check to
ensure that there is no spillage from these appliances when the Powerflue is operating
with its fan on. Check these other appliances by the procedure supplied by the
manufacturer.
12.3 Flame supervision & spillage monitoring system
The pilot unit incorporates a system which will automatically shut off the gas supply if
the pilot flame goes out or if there is insufficient oxygen due to spillage or lack of
ventilation.
Check that the system operates properly as follows;
!
Turn on the fan
.
Light the appliance and turn the control knob to “HIGH”. Leave for
one minute.
!
Turn back to “OFF” to extinguish the pilot.
Note the time when the pilot goes out.
Listen for a snap sound at the gas tap.
Note the time when the sound is heard.
This
sound is caused by an electromagnetic valve shutting off the gas supply through the tap.
The valve is located in the body of the tap. The valve should operate
within 60 seconds
of the pilot going out.
If the valve does not operate within this time limit do not allow
the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of operation.
This monitoring system, or any of its parts, must only be exchanged using Authorised
parts.
13. FINAL REVIEW
!
Carefully place the fire front castings / fire front into position.
!
Hand the literature pack, this guide and the smoke match tube to the customer.
!
Visually inspect the appliance. Clean off any marks incurred during installation.
!
Advise the customer how to operate the appliance.
!
Explain to the customer that the appliance has a flame failure & spillage monitoring
system. Point out the explanation of this system shown in the owner guide under
“Operating the Fire”. Advise that if the fire goes out for any reason, wait at least three
minutes before relighting.
!
Stress that if the monitoring system repeatedly shuts off the fire, the appliance
should be switched off and a specialist should be consulted.
!
Advise the customer that the castings, fascia, firebox and ceramic pieces can be
cleaned as described in the owner guide and that the ceramic fuel effect pieces must be
replaced as described in the installer and owner guide supplied with the ceramic fuel
effect, which you should leave with this guide.
!
Stress that no extra ceramic fuel effect pieces must be added over and above those
supplied with the appliance and that any replacements must only be the authorised
spares. Warn that ignoring this advice could cause incomplete clearance of the
Page 35
INSTALLER GUIDE