REAR PANEL CONNECTIONS
Record Start In
Record Start In will place the unit in Record mode when activated. Compatible with the Disk End Out signal from a second
unit.
min. duration: 0.5 sec.
Input
High
Low
: Active Low TTL with pull-ups or Normally Open relay
: 5V (12V max.)
: Ground
Alarm Record Reset
This feature is for future development, and has not yet been implemented.
VEXT Pulse Out
The Video External Pulse connection (VEXT) simplifies multiplexer operation by automatically synchronizing the multiplexer
and the DTL-960e. The DTL-960e sends a VEXT pulse to the multiplexer indicating that it is ready to record the next
image. The multiplexer responds by sending the next image to the Video Input on the DTL-960e.
The VEXT connection is especially beneficial for units configured with dual record speeds (Normal and Alarm).
Output
High
Low
Current out
: Active Low
: 5V
: Ground (0.8V max.)
: 50mA max. (short circuit protected)
Use of the VEXT connection is highly recommended when connecting the unit to a multiplexer.
Error Out
This feature is for future development, and has not yet been implemented.
Videoloss Out
The Videoloss Out signal is activated when the unit experiences videoloss on the selected video input (Composite or
SVHS).
In the event of videoloss,
VIDEOLOSS
will be indicated near the upper left hand corner of the primary monitor.
min. duration: 0.5 sec.
Output
High
Low
Active when On
Current out
: Open Collector
: Transistor Off
: Transistor On
: 10mA max.
Disk End Out
The Disk End Out is activated when there is 5 minutes of recording space left on the hard disk.
min. duration: 0.5 sec.
Output
High
Low
Active when On
Current out
: Open Collector
: Transistor Off
: Transistor On
: 10mA max.