Baumer_EAx_PROFINET_EN_202011_MNL.docx
70/74
www.baumer.com
11.20
7.5. Vendor-specific parameters
The following vendor-specific parameters are provided by the encoder since firmware version 1.3.0.
Index
Access
Name
Data type
Length
(in bytes)
Description
0x0005
Read-only
Temperature
Integer
1
Temperature in
degree Celsius
0x0006
Read-only
Serial number
String
32
Baumer-
specific
serial number
7.5.1.
Temperature
To read out the temperature via „read request“ the following parameters have to be set with the following
values in the „read request“.
Parameter
Length (in bytes)
Value
API
4
0x00003D00
SlotNumber
2
0x0001
SubslotNumber
2
0x0001
Index
2
0x0005
RecordDataLength
4
0x00000001
7.5.2.
Serial number
To read out the serial number
via „read request“ the following parameters have to be set with the following
values in the „read request“.
Parameter
Length (in bytes)
Value
API
4
0x00003D00
SlotNumber
2
0x0001
SubslotNumber
2
0x0001
Index
2
0x0006
RecordDataLength
4
0x00000020