8. General informations
Protect cable transducer and measuring wire as far as
possible from water. Avoid mounting with measuring wire
outlet pointing upwards (especially in outdoor applications)
to reduce risk of water entry. Freezing water can lead to
damage. Drainage holes can be opened to allow water
to drain. Prefer mounting cable transducer with drainage
holes in low position.
>3°
>3°
<3°
Ensure pulling out of measuring wire in straight direction.
Maximum misalignment ≤3°. Use pulley to limit misalign-
ment. Do not loop measuring wire around objects or allow
them to touch measuring wire. Protect measuring wire
from dirt and damage.
Ensure free rotation of measuring wire fixation to assure
optimum wire guiding.
Letting snap back of pulled out measuring wire can cause
injuries and damage of cable transducer.
10. Disposal
The cable transducer contains electronic components.
At its disposal, local environmental guidelines must be
followed.
9. Mounting
BMMS K
2.
1.
M4 DIN912 (3x)
max. 2.5 Nm
BMMS M
1.
2.
M6 DIN912 (3x)
max. 2.5 Nm
Fit cable transducer on a plain base to avoid excessive force on housing. Make sure that drainage holes are free. It is
recommended to use flat washers.