1. Identification of notes
Note
Information for intended product use.
2. Technical data
Voltage supply 10...30 VDC (UL Class 2)
Consumption w/o load: typ. 50 mA (24 VDC)
R
ø
ø = 5.5 +0.2 mm
R fix ≥18 mm
R flexible ≥57 mm
3. Intended use
The cable transducer is a precision measuring
device that is used to record linear positions and
speeds. It provides measuring values as electronic
output signals for the subsequently connected
device. It must not be used for any other purpose.
Unless this product is specially labeled, it may
not be used for operation in potentially explosive
environments.
Make sure by appropriate safety measures, that
in case of error or failure of the cable transducer,
no danger to persons or damage to the system or
operating facilities occurs. Do not directly connect
with on board supply system but with a DC/DC
converter which is released by automotive standar-
dization group.
4. Personnel qualification
Installation and assembly of this product may be performed
only by a person qualified in electronics and precision
mechanics.
5. Maintenance
The cable transducer is maintenance-free and must not
be opened up nor mechanically or electronically modified.
Opening up the cable transducer can lead to injury caused
by the spring.
6. Recommended grounding concept
screen connection
7. Terminal assignment
7.1 Cable
Colour
Signals
white (wh)
0 V
brown (bn)
+Vs
green (gn)
CAN_H
yellow (ye)
CAN_L
grey (gy)
CAN_GND
Cable 5 x 0.14 mm
2
Screen: connected to housing.
7.2 Flange connector M12, 5-pin
Pin
Non redundant
Redundant
1 n.c.
CAN_GND
2 +Vs
+Vs
3
CAN_GND
0 V
4
CAN_H
CAN_H
5
CAN_L
CAN_L
1
2
3
4
5
For customer-specific cable transducers please refer to product label and data sheet.