Troubleshooting
Malfunction alarms
Door open:
o
When the blast chiller is working, every time the door is opened
the evaporator fans stop.
o
If it is left open from 0 – 15 seconds a buzzer is sounded and
icons
7, 8, 14, 15
flash in order. The cycle is not interrupted so
by closing the door, the cycle restarts immediately.
o
If it is open from 15 seconds – 3 minutes, the cycle is paused.
The buzzer stops and sounds every 10 seconds. Icons
7, 8, 14,
15
continue to flash. When the door is closed, the cycle starts
again from where it was interrupted.
o
If it is open for more than 3 minutes, the cycle is definitively
interrupted and the appliance goes into an alarm state and all
the icons will flash. To reset the appliance you should press
buttons
(1)
and
(6)
together for a few seconds until a double
buzzer sounds and the appliance will switch off.
Power cut:
o
If the electrical current has been interrupted from 0 to 3
minutes, the appliance will automatically restart the chosen
chiller cycle once the mains electricity is restored, including the
maintenance mode.
o
If the current has been interrupted for more than 3 minutes, the
chiller cycle is interrupted and the appliance will go into an alarm
state, even during the maintenance mode.
To reset the appliance once it is in an alarm state,
press buttons
(1)
and
(6)
simultaneously for a few
seconds until a double buzzer sounds. The appliance
will then switch off.