Rev. A-021009
P/N VDC24041AA-S3-MNL
BatteryMINDer
®
Model 24041-AA-S3
Page 17
Correct polarity and a good connection will be
your reward. Attach the
BCA
to the proper battery
posts, clamps or screw terminals, depending on
type of battery.
Note
:
Temperature Compensation Sensor
Assembly (Part# ABS-248).
See pages 21 - 24
for full detailed instructions.
3.
Plug the unit’s Power cord into a standard
– grounded 120 Vac electrical outlet. The Battery
Connected LED Indicator will light
GREEN
. If it
does not light
GREEN
check the outlet to be
sure it is functioning. In addition, be sure if outlet
is controlled by a switch, no one will accidentally
shut off the power to the outlet. Check for cor-
rect polarity = (no ERROR
RED
LED Indicator). If
ERROR Indicator is lit, reverse the charger’s out
-
put connections to the battery.
4.
Charger will automatically start within 30 sec-
onds or less. The Charge – Float LED Indicator
will light
GREEN
. The charger will now begin
charging by first checking the battery to determine
its voltage and ability to accept a charge. Should
the battery not have a normal fully discharged
voltage (21.0-V minimum) the unit will begin
charging in the “Soft-Start” mode to determine if
the battery can be safely charged. If it cannot, the
Battery Connected – Error LED will flash
RED
and
charging will be stopped. Battery should be care-
fully checked under a load by a qualified person
before further attempting to charge it.
Summary of Contents for 24041-AA-S3
Page 11: ...Rev A 021009 P N VDC24041AA S3 MNL BatteryMINDer Model 24041 AA S3 Page 11 Your Notes...
Page 18: ...Rev A 021009 P N VDC24041AA S3 MNL BatteryMINDer Model 24041 AA S3 Page 18 Your Notes...
Page 24: ...Rev A 021009 P N VDC24041AA S3 MNL BatteryMINDer Model 24041 AA S3 Page 24 Your Notes...