Page 23
The chart below shows the need to regulate the output voltage of the charger to ensure against over or
under charging your battery over a wide range of temperatures. Using your At-the-Battery Sensor will
accomplish this better than any other known method.
AGM and Flooded (wet-cell) Charge and Float Voltages at Various Temperature Ranges**
Temp °F
Optimum Charge
Optimum Float
Temp °C
≥
120
28.00
26.00
≥
49
110 – 120
28.40
26.20
43 – 49
100 -110
28.60
26.40
38 – 43
90 – 100
28.80
26.60
32 – 38
80 – 90
29.00
26.80
27 – 32
70 – 80
29.40**
27.20**
21 – 27
60 – 70
29.70
27.70
16 - 21
50 – 60
30.00
28.10
10 - 16
40 – 50
30.40
28.50
4 - 10
≤
40
31.00
28.90
≤
4