USE A DIGITAL VOLTMETER ONLY:
1.
Recharge the battery with the
BatteryMINDer to ensure it is as completely
charged as possible, before you determine its
condition. Allow battery to “rest” (see pg. 9) over
-
night for a minimum of 12 hours before testing
with a digital voltmeter only.
Failure to test a “rested” (see pg. 9) battery will
cause false readings. Be certain to read and
understand all safety related instructions (pages 3
to 7) before proceeding further.
2.
Measure battery’s voltage, without any load
attached. If the voltage is less than 25.2 volts
(Typically 75% of charge) the battery may be too
heavily sulfated to be fully recoverable. If voltage
is 25.2-V or higher full recovery can be expected,
given sufficient time (average 1-2 weeks for batter-
ies that are heavily sulfated).
3.
Connect the BatteryMINDer to the battery.
4.
Charge battery to its maximum level. Allow
battery to remain for a minimum of 72 hours
before retesting. If improvement is seen, continue
until battery voltage reaches full capacity level or
no further increase is seen.