Configuring the Camera
4-42
BASLER A640
f
DRAFT
4.4.2.5 Control and Status Registers for Format 7, Mode 1
Format 7, Mode 1 is available on
A641
fc
color cameras only. The base address for each Format
7, Mode 1 camera control register is:
Bus ID, Node ID, FFFF F1F0 0100
In each Format 7, Mode 0 register description, an “Offset from the Base Address” is provided. This
is a byte offset from the above base address. The address of a Format 7, Mode 1 register equals
the above base address plus the indicated offset.
Values are stated in decimal format except when marked 0x. Values marked as 0x (e.g., 0x123)
are in hexadecimal format.
Bit 0 in each register is the most significant bit.
Register Name:
Max Image Size Inquiry
Offset from Base Address:
0x000
Field
Bit
Description
Hmax
0 ... 15
Indicates the maximum horizontal image size in pixels.
Hmax = 1624
Vmax
16 ... 31
Indicates the maximum vertical image size in pixels.
Vmax = 1234
Register Name:
Unit Size Inquiry
Offset from Base Address:
0x004
Field
Bit
Description
Hunit
0 ... 15
Indicates the increment in columns for adjusting the area of interest
width (see Section
). For example, if the Hunit is 2, the width should
be set in increments of 2.
Hunit = 2
Vunit
16 ... 31
Indicates the increment in rows for adjusting the area of interest height
(see Section
). For example, if the Vunit is 1, the height should be
set in increments of 1.
Vunit = 2
Summary of Contents for A640F
Page 1: ...USER S MANUAL Document Number DA00073201 Release Date 1 June 2005...
Page 4: ......
Page 14: ...Introduction 1 6 BASLER A640f DRAFT...
Page 20: ...Camera Interface 2 6 BASLER A640f DRAFT Figure 2 3 I O Schematic...
Page 163: ...Smart Features BASLER A640f 6 27 DRAFT Figure 6 6 Sample Text File for Use With Upload Button...
Page 180: ...Technical Support 8 2 BASLER A640f DRAFT...
Page 184: ...Revision History ii BASLER A640f DRAFT...
Page 186: ...Feedback iv BASLER A640f DRAFT...