Configuring the Camera
BASLER A640
f
4-27
DRAFT
Register Name:
Software Trigger
Offset from Base Address:
0x62C
Field
Bit
Description
Trigger
0
When the Trigger Source field of the Trigger Mode register (see page
) is set for a software trigger, this field controls the software trigger.
0 = reset the software trigger
1 = set the software trigger
(If the Trigger Mode field of the Trigger Mode register is set to 0, this
field will self clear.)
---
1 ... 31
Reserved
Register Name:
Data Depth
Offset from Base Address:
0x630
Field
Bit
Description
Depth
0 ... 7
Indicates the effective depth of the data in the transmitted images.
Depends on the current format and mode settings. Also depends on
the Color Coding ID if the camera is set for Format 7.
This field is read only.
Camera set for:
Effective data depth indicated:
Mono 8 output
8 bits/pixel
Mono 16 output
12 bits/pixel
Raw 8 output
8 bits/pixel
Raw 16 output
12 bits/pixel
4:2:2 YUV output
8 bits/component
---
8 ... 31
Reserved