Basic Operation & Standard Features
BASLER A640
f
3-11
DRAFT
3.2.6 Integrate Enabled Signal
A640
f
cameras supply an “Integrate Enabled” signal. The Integrate Enabled (IntEn) signal goes
high when exposure begins and goes low when exposure ends. This signal can be used as a flash
trigger and is also useful when you are operating a system where either the camera or the object
being imaged is movable. For example, assume that the camera is mounted on an arm
mechanism and that the mechanism can move the camera to view different portions of a product
assembly. Typically, you do not want the camera to move during exposure. In this case, you can
monitor the IntEn signal to know when exposure is taking place and thus know when to avoid
moving the camera.
By default, the IntEn signal is assigned to physical output port 0 on the camera. See Section
for a description of the electrical characteristics of the camera’s physical output ports.
The assignment of the IntEn signal to a physical output port can be changed. See Section
for more information on changing the assignment of camera output signals to physical output
ports.
L
When you use the Integrate Enabled signal, be aware that there is a delay in the rise
and the fall of the signal in relation to the start and the end of exposure. See Figure
for details.
Summary of Contents for A640F
Page 1: ...USER S MANUAL Document Number DA00073201 Release Date 1 June 2005...
Page 4: ......
Page 14: ...Introduction 1 6 BASLER A640f DRAFT...
Page 20: ...Camera Interface 2 6 BASLER A640f DRAFT Figure 2 3 I O Schematic...
Page 163: ...Smart Features BASLER A640f 6 27 DRAFT Figure 6 6 Sample Text File for Use With Upload Button...
Page 180: ...Technical Support 8 2 BASLER A640f DRAFT...
Page 184: ...Revision History ii BASLER A640f DRAFT...
Page 186: ...Feedback iv BASLER A640f DRAFT...