background image

English

Instruction and operation manual

S 530

Leak detector for pneumatic systems

Summary of Contents for S 530

Page 1: ...English Instruction and operation manual S 530 Leak detector for pneumatic systems ...

Page 2: ...ance with this manual Should the device be tampered with in any manner other than a procedure which is described and specified in the manual the warranty is cancelled and the manufacturer is exempt from liability The device is destined exclusively for the described application SUTO offers no guarantee for the suitability for any other purpose SUTO is also not liable for consequential damage result...

Page 3: ...al 8 4 2 Electrical Data 8 4 3 Performance chart 8 5 Dimensional drawing 9 6 Operating 10 6 1 Operating Principle 11 6 2 Operating Procedure 12 6 3 Electrical connection 13 7 Optional extra accessories 14 7 1 Ultrasonic tone generator 14 8 Maintenance 15 9 Disposal or waste 15 10 Warranty 15 S 530 3 ...

Page 4: ...regarding this manual or the product please contact the manufacturer WARNING Compressed air Any contact with quickly escaping air or bursting parts of the compressed air system can lead to serious injuries or even death Avoid that persons get hit escaping air or bursting parts of the system WARNING Laser pointer Do not point into the eyes with the laser This can lead to serious injuries particular...

Page 5: ... areas Please observe the national regulations before during operation Remarks It is not allowed to disassemble the product ATTENTION Measurement values can be affected by malfunction The product must be used properly and frequently maintained otherwise it may lead to wrong measurement values which can lead to wrong results Avoid condensation on the leak detector element as this will affect the ac...

Page 6: ...1 Safety instructions For the storage the humidity has to be 90 no condensation 6 S 530 ...

Page 7: ...ill leak through small openings The integrated laser pointer helps to spot the leak from a distance The S 530 leak detector is not developed to be used in explosive areas For the use in explosive areas please contact the manufacturer The S 530 leak detector is mainly used in compressed air systems in industrial environment 3 Features Leak detection in compressed air refrigerants and any gases Insu...

Page 8: ...Laser pointer on About 4 hours with Laser pointer on Charging temperature 10 C 45 C Charging time Around 1 5 hours Material of the detector PC ABS Dimensions See dimensional drawing on the next page Display 3 colour black mask LCD 10 level Laser pointer 640 660 nm wavelength 0 4 0 5 mW output power Weight 2 5 kg full set 4 2 Electrical data Power supply Internal NiMH rechargeable battery 4 3 Perfo...

Page 9: ...5 Dimensional drawing 5 Dimensional drawing S 530 9 ...

Page 10: ... head set A554 0102 1 Focus tube and focus tip A530 0101 1 Cable to detach sound probe from instrument A553 0101 1 Battery charger A554 0001 1 Transport case A554 0101 Remark The sensor unit can be unplugged from the main instrument by pulling the unit out of the holder A separate coiled extension cable is used to connect the sensor to the main unit For this have a look at the picture above 10 S 5...

Page 11: ... the frequency the more energy it contains But higher frequencies can not be transported in air that far That is why the leak detector operates at a centre frequency of 40 kHz which compromises an optimum between energy and distance Frequencies below and above are cut in order to minimize the noise level S 530 11 ...

Page 12: ... Power button 2 The Display of the S 530 look like the picture on the left side The laser pointer is off the Display will show you the battery level the segments green till red User can change the sensitivity with the wheel 3 To activate the laser please press the button which is shown on the left side 12 S 530 ...

Page 13: ... till the exact location is found 7 For difficult attainable location you can use the separate coiled extension cable 6 3 Electrical connection Either the headphone or the charger can be connected to S 530 at a time Remark If the instrument has not been used for more than 2 months the battery might be over discharged Connect the battery charger and wait about 2 3 minutes until the display can show...

Page 14: ...h can be detected by the S 530 Thats why a leak detection in a system without overpressure is possible Specification Frequency 40 kHz 10 Automatically shut down after 10 min 20 Power supply internal E Block 6LR61 9 V For example Leak test at a tank If an US tone generator is inside of a tank the ultrasonic which is produced by the generator can flow through leaks and detected by the S 530 14 S 530...

Page 15: ...acturer 10 Warranty SUTO provides a warranty for this product of 24 months covering the material and workmanship under the stated operating conditions from the date of delivery Please report any findings immediately and within the warranty time If faults occurring during the warranty time SUTO will repair or replace the defective unit without charge for labour and material costs but there is a cha...

Page 16: ...s are undertaken by third parties or unauthorised persons If the serial number has been changed damaged or removed Other claims especially those for damage occurring outside the instrument are not included unless responsibility is legally binding Warranty repairs do not extend the period of warranty ATTENTION Batteries have a reduced warranty time of 12 month 16 S 530 ...

Page 17: ...S 530 17 ...

Page 18: ...18 S 530 ...

Page 19: ...S 530 19 ...

Page 20: ...ad Sheung Shui N T Germany Hong Kong Tel 49 0 7631 936889 0 Tel 852 2328 9782 Fax 49 0 7631 936889 19 Fax 852 2671 3863 Email sales suto itec com Email sales suto itec asia Website http www suto itec com Website http www suto itec com All rights reserved Modifications and errors reserved S530_im_en_2018 1 20 S 530 ...