![Basler A102f User Manual Download Page 87](http://html1.mh-extra.com/html/basler/a102f/a102f_user-manual_2707387087.webp)
Configuring the Camera
BASLER A102
f
4-25
DRAFT
4.4.2.3 Error Status Registers for Feature Control
As defined in the IIDC specification, each field in this register is an error or warning flag for the
corresponding feature control register. If a bit = 1, the mode and/or value of the corresponding
feature control register has an error or warning. If a bit = 0, no error or warning is present. Each
field in this register will be updated whenever the corresponding feature control register is
updated. If a bit = 1, we strongly recommend checking the corresponding control register.
On
A102
f
and
A102
fc
cameras, a feature’s bit will become 1 when the feature’s setting is outside
the specified range of allowed settings, that is, the setting is lower than the allowed minimum or
higher than the allowed maximum. If this situation occurs,
A102
f
and
A102
fc
cameras will continue
image capture and you will see the undesired effects that result from the setting.
Register Name:
Feature Control Error Status High
Offset from Base Address:
0x640
Field
Bit
Description
Brightness
0
Indicates a brightness control error on the A102f or A102fc.
0 = no error present
1 = A setting in the brightness control register (see page
4-20
) is out-
side of the allowed range
This field is read only.
Auto Exposure
1
Not used on the A102f or A102fc. This bit should be ignored.
Sharpness
2
Not used on the A102f or A102fc. This bit should be ignored.
White Balance
3
Indicates a white balance control error on the A102fc.
0 = no error present
1 = A setting in the white balance control register (see page
4-21
) is
outside of the allowed range
This field is read only.
Hue
4
Not used on the A102f or A102fc. This bit should be ignored.
Saturation
5
Not used on the A102f or A102fc. This bit should be ignored.
Gamma
6
Not used on the A102f or A102fc. This bit should be ignored.
Shutter
7
Indicates a shutter control error on the A102f or A102fc.
0 = no error present
1 = A setting in the shutter control register (see page
4-22
) is outside
of the allowed range
This field is read only.
Gain
8
Indicates a gain control error on the A102f or A102fc.
0 = no error present
1 = A setting in the gain control register (see page
4-23
) is outside of
the allowed range
This field is read only.
Iris
9
Not used on the A102f or A102fc. This bit should be ignored.
Focus
10
Not used on the A102f or A102fc. This bit should be ignored.
Temperature
11
Not used on the A102f or A102fc. This bit should be ignored.
Summary of Contents for A102f
Page 1: ...USER S MANUAL Document Number DA00063006 Release Date 7 December 2010 ...
Page 4: ......
Page 25: ...Basic Operation Standard Features BASLER A102f 3 3 DRAFT Figure 3 2 Block Diagram ...
Page 62: ...Basic Operation Standard Features 3 40 BASLER A102f DRAFT ...
Page 166: ...Mechanical Considerations 7 6 BASLER A102f DRAFT ...