![Basler A102f User Manual Download Page 127](http://html1.mh-extra.com/html/basler/a102f/a102f_user-manual_2707387127.webp)
Smart Features
BASLER A102
f
6-5
DRAFT
Example
Determine the address of the “CRC Checksum” smart feature which has a CSR GUID of:
3B34004E - 1B84 - 11D8 - 83B3 - 00105A5BAE55
D1:
0x3B34 004E
D2:
0x1B84
D3:
0x11D8
D4[0]:
0x83
D4[1]:
0xB3
D4[2]:
0x00
D4[3]:
0x10
D4[4]:
0x5A
D4[5]:
0x5B
D4[6]:
0xAE
D4[7]:
0x55
Step 1: Write the CSR GUID to the Smart Features Inquiry Register
Assuming that the address for the Access Control Register is 0xFFFF F2F0 0000, perform the
following quadlet write operations to the Smart Features Inquiry Register
a. Write quadlet data 0x3B34 004E to 0xFFFF F2F0 0010
(D1)
b. Write quadlet data 0x11D8 1B84 to 0xFFFF F2F0 0014
(D3 | D2)
c. Write quadlet data 0x1000 B383 to 0xFFFF F2F0 0018
(D4[3] | D[0])
d. Write quadlet data 0x55AE 5B5A to 0xFFFF F2F0 001C
(D4[7] | D[4])
Instead of performing four quadlet write operations, one block write operation can be performed.
Step 2: Read the start address for the smart feature from the Smart Features Address register
a. Read quadlet data from 0xFFFF F2F0 0020 (Address Low)
b. Read quadlet data from 0xFFFF F2F0 0024 (Address High)
If both Address Low and Address High return zero, the camera doesn’t support the CRC
checksum feature. Assuming the read operations yielded Address Low = 0xF2F0 0038 and
Address High = 0x0000 FFFF, the CRC Checksum feature CSR’s address is 0xFFFF F2F0 0038.
Summary of Contents for A102f
Page 1: ...USER S MANUAL Document Number DA00063006 Release Date 7 December 2010 ...
Page 4: ......
Page 25: ...Basic Operation Standard Features BASLER A102f 3 3 DRAFT Figure 3 2 Block Diagram ...
Page 62: ...Basic Operation Standard Features 3 40 BASLER A102f DRAFT ...
Page 166: ...Mechanical Considerations 7 6 BASLER A102f DRAFT ...