![Basler A102f User Manual Download Page 18](http://html1.mh-extra.com/html/basler/a102f/a102f_user-manual_2707387018.webp)
Camera Interface
2-4
BASLER A102
f
DRAFT
2.2
Cables
The maximum length of the IEEE 1394 cable used between the camera and the adapter in your
PC or between the camera and a 1394 hub is 4.5 meters as specified in the IEEE 1394 standard.
Standard, shielded IEEE 1394 cables must be used.
The maximum length of the I/O cable is at least 10 meters. The cable must be shielded and must
be constructed with twisted pair wire. Close proximity to strong magnetic fields should be avoided.
2.3
Camera Power
Power must be supplied to the camera via the IEEE 1394 cable. Nominal input voltage is
+12.0
_
VDC, however, the camera will operate properly on any input voltage from +8.0 VDC to
+36.0 VDC as specified in the IEEE 1394 standard. Maximum power consumption for the
A102
f
is
3.5 W at 12 VDC. Ripple must be less than 1%.
2.4
IEEE 1394 Device Information
The
A102
f
uses an IEEE 1394a - 2000 compliant physical layer device to transmit pixel data.
Detailed spec sheets for devices of this type are available at the Texas Instruments web site
(www.ti.com).
Caution!
Use only standard IEEE 1394 connectors.
The polarity of the input power to the camera must be as shown in Table
2-1
.
Do not
reverse the input power polarity. Reversing the polarity will
damage the camera.
Summary of Contents for A102f
Page 1: ...USER S MANUAL Document Number DA00063006 Release Date 7 December 2010 ...
Page 4: ......
Page 25: ...Basic Operation Standard Features BASLER A102f 3 3 DRAFT Figure 3 2 Block Diagram ...
Page 62: ...Basic Operation Standard Features 3 40 BASLER A102f DRAFT ...
Page 166: ...Mechanical Considerations 7 6 BASLER A102f DRAFT ...