![Basler A102f User Manual Download Page 159](http://html1.mh-extra.com/html/basler/a102f/a102f_user-manual_2707387159.webp)
Smart Features
BASLER A102
f
6-37
DRAFT
Example
Assume that you have set the Duration Value field of the Strobe 0 control register to 423. Also
assume that you have set the Duration Time Base field in the Strobe Time Base CSR to 5. In this
case:
Strobe 0 Duration = (Strobe 0 Duration Value Setting) x (Strobe Duration Time Base)
Strobe 0 Duration = (423) x (5/1024 ms)
Strobe 0 Duration = 2.07 ms
Control and Status Register for the Strobe Time Base Feature
L
There is only one setting for the strobe delay time base and this single setting is used
by all four of the available strobe outputs.
There is only one setting for the strobe duration time base and this single setting is
used by all four of the available strobe outputs.
The strobe time base smart feature does not add information to the image data
stream and can be accessed even when the extended data stream feature (see Sec-
tion
6.7.1
) is disabled.
The strobe time base smart feature can be enabled regardless of the video format.
Name
Strobe Time Base
Address
See “Determining the Address of Smart Features CSRs” on page
6-4
.
CSR GUID
E77E6336 - E617 - 11D8 - 9653 - 00105A5BAE55
Position
Field
Bit
Description
0
Presence Inq
(Read only)
[0]
Presence of the shutter time base feature
0: Not Available 1: Available
-----
[1 ... 15]
Reserved
Duration
Time Base
(Read / write)
[16 ... 23]
The value in this field is an integer value and can
range between 1 and 85.
The value sets the duration time base in units of
1/1024 ms.
Example: If the value in this field is set to 14, the du-
ration time base will be 14/1024 ms (~ 13.7 µs)
Default = 1
Delay Time Base
(Read only)
[24 ... 31]
The value in this field is an integer value and can
range between 1 and 85.
The value sets the delay time base in units of
1/1024 ms.
Example: If the value in this field is set to 14, the de-
lay time base will be 14/1024 ms (~ 13.7 µs)
Default = 1
Summary of Contents for A102f
Page 1: ...USER S MANUAL Document Number DA00063006 Release Date 7 December 2010 ...
Page 4: ......
Page 25: ...Basic Operation Standard Features BASLER A102f 3 3 DRAFT Figure 3 2 Block Diagram ...
Page 62: ...Basic Operation Standard Features 3 40 BASLER A102f DRAFT ...
Page 166: ...Mechanical Considerations 7 6 BASLER A102f DRAFT ...