base engineering FWG09 Assembly Instructions Manual Download Page 23

 

FWG09I Assembly instructions 

 

 

23 

Manufacturer's Declaration 

 
 
The manufacturer 
base engineering GmbH 
Querstücken 5 
22851 Norderstedt 
 
hereby declares that the following product: 

The emergency call system as a combination of an emergency call device (FWG05/FWG09/FWG12) 
connected to a mobile gateway unit (GSM10/GSM13) or landline connection/converted AB interface 
via the public telephone network, 

with the proviso that the telephone numbers and object numbers are not publicly known, 

corresponds to security level SL-0 and according to the normative Appendix A of DIN EN IEC 62443-3-
2 no further measures to protect against cyber threats are to be taken. 
 
Based on Table B.2 and B.3 Appendix B of DIN EN IEC 62443-3-2, the following risk matrix was 
determined for undiminished cyber risk: 
 
  

 

Severity of the potential impact on operations, financial impact or health

 

Likelihood of occurrence 

Operations 
low 

Operations 
middle 

Operations 
high 

Financial 
low 

Financial 
middle 

Financial 
high 

Health 
low 

Health 
middle 

Health 
high 

Almost certain (> 10⁻¹ per 
year) 

Middle 

High 

High 

Middle 

High 

High 

Middle 

High 

High 

Likely (10⁻¹ to 10⁻³ per 
year) 

Middle 

High 

High 

Middle 

High 

High 

Middle 

High 

High 

Possible  (10⁻³ to 10⁻⁴ per 
year) 

Low 

Middle 

High 

Low 

Middle 

High 

Low 

Middle 

High 

Unlikely (10⁻⁴ to 10⁻⁵ per 
year) 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

Rare (< 10⁻⁵ per year) 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

Low 

 
In order to further reduce the residual risk of people being trapped in the event of a successful attack 
on the emergency call system, the operator can optionally use an automatic shutdown (ASM20) of 
the elevator system to technically ensure that the elevator is shut down if the emergency call device 
fails. 
Date: 20.06.2023 
 
 
 
 
_______________________________  
(Signature)  

Carsten Seemann, CEO 

 

 

Summary of Contents for FWG09

Page 1: ...Hotline phone 040 790 261 790 040 529 811 30 040 529 811 31 Website https base engineering com Version 2023 06 28 1 FWG09 Assembly instructions Connections with adapter board...

Page 2: ...FWG09I Assembly instructions 2 Direct connections without adapter board...

Page 3: ...rect the sound outlet opening of the FWG09 to the side of the shaft wall never up The connectors should point downwards Avoid sound reflections on plane surfaces that are too close keep at least 20cm...

Page 4: ...pter board pull the orange plug 2 Press the buttons Option and Option simultaneously A shutdown sound plays This is important as otherwise the unit will continue to run on battery mode and the battery...

Page 5: ...ns of an external power supply This can be up to 60 volts the maximum current is 100mA The switch output lies at position B C the negative terminal is always switched The ground of the power supply of...

Page 6: ...xternal power supply This can be up to 60 volts the maximum current is 100mA The switch output lies at position B D the negative terminal is always switched The ground of the power supply of the LEDs...

Page 7: ...connected to indicate that the alarm has been misused This is only evaluated with the car alarm button 1 A distinction can be made as to whether a misuse message should be sent to the call center or...

Page 8: ...by outputting a potential free illustration of the alarm button replacing the missing second level The internal circuit of the FWG09 is used to switch the connected alarm button to the recognition cir...

Page 9: ...m is reported as a normal alarm On misused alarm is reported as such Suppressed misused alarm is not reported at all Fire alarm As long as voltage is supplied an announcement is played to leave the li...

Page 10: ...is dialed before each telephone number A pause of 1 2 seconds is included after the 9 9 without pause A 9 is dialed before each telephone number The entire number including 9 is dialed in a row witho...

Page 11: ...pictograms alarm button and speaker optional microphone for In wall 200400001480 Panel 3 with emergency light and pictograms for On wall 200400001460 Panel 4 with emergency light and pictograms for I...

Page 12: ...hind the elevator panel without opening the panel you can also access the service menu via DTMF To do this call the device and type in Object Car 0 after the answer tone for example 7191710 for the de...

Page 13: ...8 The software variant 1 complies with EN81 28 Variants 2 2A 3 3A and 3B are not compliant with EN81 28 and are thus to be set at one s own responsibility Technical requirements When choosing no evalu...

Page 14: ...esponds to all sent DTMF commands regardless of this Program 3A Same as program 3 the object number is announced twice before establishing the voice connection Program 3B Like program 3 but a voice co...

Page 15: ...atively you can temporarily change the program variant to 2 in the service menu while programming If the master PIN is successfully entered the object number is announced Individual units or car 1 for...

Page 16: ...ou then enter the PIN with a both in front and behind or Car the announcement Messages cleared is made for technical messages This means that the message has been successfully transmitted for that par...

Page 17: ...r 1 And the instruction Please enter 1 to accept the emergency call 3 Establish a voice communication 1 Response from unit Voice connection 1 on Please enter 0 to terminate the voice connection 4 Spea...

Page 18: ...pplied at the misuse input Recommendations for action Establish voice communication and respond accordingly Emergency over car n Programs 1 2 2A An active emergency call has been marked as finished on...

Page 19: ...The battery is actually missing or is inserted incorrectly Recommendations for action Take the lift out of operation Battery broken car n Programs 1 2 2A The battery can no longer be charged or in its...

Page 20: ...r more cars using the code transmitter This is an older method to connect via telephone to units that only support call center communication Recommendations for action Document the message with date a...

Page 21: ...onfuse with Battery broken car n Recommendation for action Arrange for battery replacement for the GSM10 GSM13 Module within one week T V Certification The conformity of FWG09 to EN81 28 has been cert...

Page 22: ...of the EMC Directive 2014 30 EU Elevator Directive 2014 33 EU including the changes which applied at the time of the declaration The following harmonised standards have been applied Electromagnetic C...

Page 23: ...er risk Severity of the potential impact on operations financial impact or health Likelihood of occurrence Operations low Operations middle Operations high Financial low Financial middle Financial hig...

Page 24: ...FWG09I Assembly instructions 24 This page is intentionally left blank...

Page 25: ...erwise also generate All these messages are reported to the receiving station and must be acknowledged via the DTMF commands on the telephone keypad because the emergency call system will continue to...

Page 26: ...the internal emergency power supply is no longer known For the reasons set out above this program version is not compatible with the obligations of an operator even with supplementary measures and th...

Reviews: