![base engineering FWG09 Assembly Instructions Manual Download Page 20](http://html1.mh-extra.com/html/base-engineering/fwg09/fwg09_assembly-instructions-manual_4470237020.webp)
FWG09I Assembly instructions
20
Recommendations for action: The emergency call no longer works, shut down the lift system.
Wire broken alarm button 2 car n (Program 1)
With the “
cable break monitored
” setting, the unit no longer sees the resistor on the hoistway
buttons.
Recommendations for action: The emergency call no longer works, shut down the lift system.
Alarm button 1 jammed car n (Program 1)
The alarm button in the car is being permanently pressed. Either the button is jammed mechanically
or there is a fault with the interconnecting cable to the unit.
Recommendations for action: Verify that the emergency call button works, if necessary shut down
the lift system.
Alarm button 2 jammed car n (Program 1)
The hoistway button is being permanently pressed. Either the button is jammed mechanically or
there is a fault in the interconnecting cable to the unit.
Recommendations for action: The emergency call no longer works, shut down the lift system.
Code transmitter call (Program 1)
Someone called the emergency call system and set up a voice communication to one or more cars
using the code transmitter. This is an older method to connect via telephone to units that only
support call center communication.
Recommendations for action: Document the message with date and time, no further action required.
Microphone and speaker test failed car n (Program 1)
The self-test of the microphone and loudspeaker has failed.
Recommendations for action: Try to initiate an emergency call and test the voice communication
thoroughly in both directions. If problems occur shut down the lift system, otherwise inform the
maintenance company.
Malfunction warning car n (Program 1)
The misuse input is set to “
malfunction warning
” and there is a voltage on it.
Recommendations for action: This is a general error message that is fed to the emergency call device
from outside. The recommended action therefore depends on what is connected to the PSS09.
Final call GSM (Programs 1, 2, 2A)
The GSM10/GSM13 module is currently running in battery mode and reports a last call for help
approximately 20 minutes before switching itself off. This message does not refer to PSS09 itself but
to the GSM10/GSM13 module. Please do not confuse with “
Final call car n
”
Recommendations for action: Call the car to detect trapped persons. Solve the cause of the power
failure.