Battery missing GSM (Programs 1, 2, 2A)
The battery of the GSM10/GSM13 module is no longer detected. This message does not refer to
PSS09 itself but to the GSM10/GSM13 module. Please do not confuse with “
Battery missing car n
”.
Recommendations for action: Take the lift out of operation.
Battery broken GSM (Programs 1, 2, 2A)
The battery can no longer be charged or in its fully charged state will shortly no longer reach its
minimum capacity for an hour of emergency power supply. This message does not refer to PSS09
itself but to the GSM10/GSM13 module. Please do not confuse with “
Battery broken car n
”
Recommendation for action: Arrange for battery replacement for the GSM10/GSM13 Module within
one week.
TÜV Certification
The conformity of FWG09 to EN81-28 has been certified by TÜV Austria.
Technical specifications
Dimensions without tabs (L×W×H)
15cm×8,2cm×4cm
Dimensions with tabs (L×W×H)
17,4cm×10,6cm×4cm
Weight
260g without batteries, 310g with batteries
Degree of protection
IP20
Power supply connection
Spring strip female connector 3.81 mm pitch, 2 poles
Power supply
10-28V DC
Power consumption mains
Max. 600mA
Battery (without emergency light)
NiMH, 2 cells, at least 1500mAh
Battery (with emergency light)
NiMH, 2 cells, at least 2000mAh
Telephone line connection
Spring strip female connector 3.5 mm pitch, 2 poles
Temperature range
0°C to +40°C
Humidity
30% - 90%